Captus® Well Liner
Well liner for the Captus Thyroid Update System.
Well liner for the Captus Thyroid Update System.
Thyroid Uptake System
A comprehensive Nuclear Medicine Measurement System, with specific software modules for thyroid uptake, bioassay, wipe tests, automated quality assurance tests, and isotope library. Includes a fully functional 1024 channel MCA with auto and manual calibration. Timed activity mode features a programmable repetitive timed measurement program.
The Captus 4000e unit is a comprehensive Nuclear Medicine Measurement System, with specific software modules for thyroid uptake, bioassay, wipe tests, automated quality assurance tests, and isotope library. The system includes a fully functional 1024 channel MCA with auto and manual calibration. Timed activity mode features a programmable repetitive timed measurement program. Improved menu-driven workflow and large 20" color touch screen streamlines user interface.
The optional fully integrated DICOM interface communicates directly with hospital information systems, and can transfer patient, wipe test, and QC data. Custom Protocol is included as standard, and Microsoft Office Professional 2010 software is optional.
New and improved stand provides ergonomically adjustable monitor and easy-to-position articulating collimator arm. Four sided comfortable handle grips and swivel wheels ensure easy mobility. PC can be attached to either right or left side to optimize workspace.
5430-30151 | Captus® 4000e Thyroid Uptake System Only |
5430-30152 | Captus® 4000e Thyroid Uptake System with 1″ Well |
5430-30154 | Captus® 4000e Thyroid Uptake System with 2″ Well |
5430-00007 | Captus® 4000e DICOM Interface |
Revised April 3, 2024-adding risk of retention plate failure
Serial Numbers 940001-940547
Shipped Between August 2015 and April 2019
Capintec, a Mirion Medical Company, has issued a Safety Alert regarding reports of spring arm failures and retention plate failures with Captus 4000e Thyroid Uptake Systems. It is believed certain systems shipped between August 2015 and April 2019 could fail due to a broken tension bolt inside the spring arm or retention plate failure.
Review this Revised Safety Alert notification for preventative actions and next steps.
Please complete this short form to stay informed on next steps.
Expanded April 3, 2024
Serial Numbers 940548-941398
Shipped Between August 2019 and February 2024
Capintec, a Mirion Medical Company, is expanding a Safety Notice for potential failure of retention plate to all systems system shipped through February 2024
Review this Safety Alert notification for preventative actions and next steps.
Please complete this short form to stay informed on next steps.