The dosimeters are equipped with two so-called thermoluminescence detectors, each of which is individually calibrated. One of the detectors is used to determine Hp(10), the personal dose equivalent at a depth of 10 mm in soft tissue. This quantity is a good approximation of the effective dose received. The other detector determines Hp(0.07), the personal dose equivalent at a depth of 0.07 mm. This quantity gives a good indication of the skin dose received.
Detectors: | MCP-Ns or MTS-100 |
Mounting options: | Various, including via a clip |
Sterilizability: | Must not be sterilized |
Disinfectability: | Alcohol consumption is permitted |
Change dosimeters: | 26, 13 or 4 times a year |
Measured variable: | Hp(10) and Hp(0.07) in mSv |
Photon detection limits: | 0.03 mSv (at 2-weekly periodicity) 0.04 mSv (at 4-weekly periodicity) 0.08 mSv (at 3-monthly periodicity) |
Maximum photon dose range: | 1 Sv |
Energy range photons: | 30 keV to 1.3 MeV |
Energy and angle dependence: | See images below |
Explanation of personal dosimetry >>
Contact